De’Longhi Magnifica Evo: Pump Runs but No Water Comes Out – Finding a Scaled Hose
A De’Longhi Magnifica Evo (type ECAM290.83.TB) came onto the bench with a classic complaint: the pump could be heard working, but no water came out anywhere. The cause turned out to be simple and cheap to fix, but finding it took a methodical check of the whole water path. This is the step-by-step log of that fault-finding, with photos and a short video.

The symptoms
With the tank out, the panel showed the red water-tank warning, which is normal. With a full tank fitted, the machine moved on to the “water circuit empty” warning (jug icon plus the red triangle) and lit Hot water, asking for the circuit to be filled. Pressing Hot water made the pump run, but nothing came out of the hot water spout and the warning stayed on.


When the pump runs but no water arrives, there are only two possibilities: the pump is not getting water (intake side), or it is pushing water into a blockage (outlet side). The quickest way to find out is to follow the water from the tank onwards and test each section in turn.
Safety first
Unplug the machine before removing panels or disconnecting hoses. Mains voltage is present on the pump, valves and power board, and the thermoblock and its hoses can be very hot if the machine has just been running. Any test with the pump running and a hose disconnected should be done with the hose aimed into a container and hands clear of live parts.
Step 1: Tank and tank valve
Make sure the tank is fully seated and its bottom valve opens freely when the tank is pushed in. A stuck tank valve or a blocked strainer in the tank seat is the simplest cause of “no water”, so it is ruled out first.
Step 2: Flowmeter and pump (intake side)
On this machine the water goes from the tank through the flowmeter and then into the Ulka EP5GW pump (230 V, 48 W). The flowmeter is marked “H ø1.2 mm”: it contains a 1.2 mm jet, so with the hose disconnected after it, water only drips out under gravity even when everything is clean. A slow drip at that point proves nothing on its own.

The real test is the pump outlet. With the outlet hose disconnected and pointed into a container, the pump delivered a strong, steady stream. That confirms the tank, flowmeter and pump are all fine, so the blockage must be after the pump.
Step 3: After the pump – thermoblock and outlet hose
After the pump, water passes through the thermoblock (the heater) and then out through a thin, stiff high-pressure hose to the hot water / steam valve. This hose is held by a brass ferrule and O-ring at the thermoblock end.

Disconnecting this hose at the thermoblock showed the problem: the hose was blocked with limescale. The pump was pushing water into a dead end, so nothing could reach the spout and the machine never saw the circuit fill.


The fix
The hose was removed and the scale was cleared along its entire length, not just at the ends, as scale builds up further inside the hose as well. It was cleaned in two ways: mechanically with a thin wire pushed through the bore to break up the scale, and by injecting descaler with a syringe to dissolve and flush out what was left. Once water passed freely, the hose was refitted with the ferrule and O-ring seated correctly.
After reassembly, pressing Hot water filled the circuit and water flowed from the spout in a steady stream. The machine then heated up, finished its rinse and was ready to make coffee.



Why it happens and how to prevent it
- Hard water leaves limescale in the hottest parts of the circuit first: the thermoblock and the narrow hoses straight after it.
- A descaling cycle can only clean where the solution can flow. Once a hose is fully blocked, the descaler cannot get through and the hose has to be cleared by hand.
- Descale when the machine asks for it, and do not ignore the warning for weeks.
- Use the water hardness setting and a water filter if your water is hard.
Quick checklist: pump runs, no water
- Tank seated, tank valve opens, strainer clear.
- Pump outlet disconnected: strong stream? If yes, the intake side and pump are fine.
- If no stream: check flowmeter jet (1.2 mm) and the pump.
- If the stream is good: check the thermoblock and the hoses after it for scale.
- Clear the blocked section completely (thin wire plus descaler by syringe), reassemble, then prime with Hot water.

Related: DeLonghi Magnifica Not Making Coffee – Brew Unit, Grinder and Water Problems